We have state-of-the-art equipment. Our products are exported for the USA, the UK and so on, enjoying a fantastic status among the clients for Primers Oligonucleotides, 192 Channel Synthesizer, Acn, Our Lab now is "National Lab of diesel engine turbo technology " , and we own a professional R&D team and complete testing facility.
Special Design for Solid Phase Nucleic Acid Extraction - Phosphoramidite Dissolving Equipment – Honya Detail:

Five Channel

Introduction

It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis performance. Because the amidite should avoid contacting with the moisture. If the amidite are in the high humidity environment. The synthesis efficiency will be influenced.

The opened reagent and amidite should be dried with molecular trap.

Phosphoramidite Dissolving Equipment new01
Phosphoramidite Dissolving Equipment new00

12 Channel Dissolving Instrument

Specification

1. It suitable for various bottle types, the dissolving volume of the bottle is 0.5-45ml.
2. Configure the number of liquid inlet bottles according to customer needs (the standard volume is 4L reagent bottles), with professional bottle caps, and users can allocate liquid positions by themselves.
3. All pipelines, joints and key positions are made of corrosion-resistant materials.
4. Each bottle is equipped with an independent valve, and the valve adopts the Burkert (German).
5. Add steel needles to the mouth, one for adding liquid, one for exhausting, and one for cleaning steel needles.
6. Each channel works independently.
7. Electronic valve calibration system.
8. There is a waste liquid groove to facilitate the collection of waste liquid when cleaning the steel needle.
9. There is an independent, freely movable acetonitrile pipeline for washing or free liquid injection, the length is 30cm~40cm.

Phosphoramidite
Amidites-Dissolved-Equipment00

And we can also provide the 14 Channel, 18 Channel, and other model according to your requirements.


Product detail pictures:

Special Design for Solid Phase Nucleic Acid Extraction - Phosphoramidite Dissolving Equipment – Honya detail pictures

Special Design for Solid Phase Nucleic Acid Extraction - Phosphoramidite Dissolving Equipment – Honya detail pictures


Related Product Guide:

Innovation, excellent and reliability are the core values of our business. These principles today extra than ever form the basis of our success as an internationally active mid-size company for Special Design for Solid Phase Nucleic Acid Extraction - Phosphoramidite Dissolving Equipment – Honya , The product will supply to all over the world, such as: Morocco, Lisbon, United States, Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question items they do not understand. We break down people barriers to ensure you get what you want to the level you expect, when you want it. Faster delivery time and the product you want is our Criterion .
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Dinah from Netherlands - 2017.11.29 11:09
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Frank from Brasilia - 2018.09.12 17:18
    Write your message here and send it to us