Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya

Application:


Product Detail

Product Tags

Related Video

Feedback (2)

Our items are commonly identified and trusted by customers and may fulfill continuously switching economic and social wants of Large Scale Desalting Column, 6 Channel Synthesizer, Oligo Nucleic Acid, Should you be on the lookout forever Quality at a very good price tag and timely delivery. Do speak to us.
Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya Detail:

Five Channel

Introduction

It is used in dissolving the amidite in none-water environment, which is suitable for different standard amidite bottle. The bottle dissolution volume can reach 5-450ml. The quantities of bottle can be customized according to customer’s need. The valve of this equipment we adopts BURKET brand from Germany, and one bottle for one valve. We recommend to install the dehumidifier in lab with high humidity. It can make sure the amidite reaches the best synthesis performance. Because the amidite should avoid contacting with the moisture. If the amidite are in the high humidity environment. The synthesis efficiency will be influenced.

The opened reagent and amidite should be dried with molecular trap.

Phosphoramidite Dissolving Equipment new01
Phosphoramidite Dissolving Equipment new00

12 Channel Dissolving Instrument

Specification

1. It suitable for various bottle types, the dissolving volume of the bottle is 0.5-45ml.
2. Configure the number of liquid inlet bottles according to customer needs (the standard volume is 4L reagent bottles), with professional bottle caps, and users can allocate liquid positions by themselves.
3. All pipelines, joints and key positions are made of corrosion-resistant materials.
4. Each bottle is equipped with an independent valve, and the valve adopts the Burkert (German).
5. Add steel needles to the mouth, one for adding liquid, one for exhausting, and one for cleaning steel needles.
6. Each channel works independently.
7. Electronic valve calibration system.
8. There is a waste liquid groove to facilitate the collection of waste liquid when cleaning the steel needle.
9. There is an independent, freely movable acetonitrile pipeline for washing or free liquid injection, the length is 30cm~40cm.

Phosphoramidite
Amidites-Dissolved-Equipment00

And we can also provide the 14 Channel, 18 Channel, and other model according to your requirements.


Product detail pictures:

Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya detail pictures

Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya detail pictures


Related Product Guide:

The organization keeps on the procedure concept "scientific management, high quality and efficiency primacy, purchaser supreme for Wholesale Discount Cholesterol Labeling - Phosphoramidite Dissolving Equipment – Honya , The product will supply to all over the world, such as: Niger, Islamabad, Costa Rica, Being the top solutions of our factory, our solutions series have been tested and won us experienced authority certifications. For additional parameters and item list details, be sure to click the button to acquire additional nformation.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Muriel from French - 2017.09.26 12:12
    The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
    5 Stars By Honorio from Qatar - 2017.08.18 18:38
    Write your message here and send it to us